50Hz 3 Phase Diesel Power Silent Diesel Generator 80 kVA for Emergency Power

Boost your emergency power supply with our 50Hz 3 Phase Diesel Power Silent Diesel Generator 80 kVA. We are a factory specializing in reliable generators.
Request a Quote

PRODUCTS DETAILS

Basic Info.

Model NO.
GF/GFS-P64KW
Output Type
AC Three Phase
Speed
Speed
Conditions of Use
Land Use
Usage
Common Units, Standby Unit, Emergency Crew
Landuse Type of Unit
Low Noise Automation Type
Excitation Mode
AC Rotating Exciter
Engine Model
1006tg2a
Alternator
Stamford
Model
Open Type/Silent Type/Trailer Type/Container Type
Fuel Tank
8 Hours Base Fuel Tank
Controller
Comap/Smartgen
Alternative
Installing with ATS
Color
Depends on
Frequency
50Hz
Voltage
400V/230V 380V/220V 3 Phase
Transport Package
Wooden Package
Specification
10CBM
Trademark
Gspark
Origin
Fujian
HS Code
8502
Production Capacity
2500/Month

Product Description

Brief introduction:  Genspark Equipment Co.,Ltd mainly Supply Diesel Generator Set and Gas Generator set,including in Famous brands,Deutz,Doosan,MTU,ShangHai Diesel,YangDong etc,raning from 10KW-2000KW Outputs.Having Open type,Silent type,Container type and trailer type generator models.

With more than 10 years experience on supplying Generator sets,We always offer Most Suitable Products for Customers Abroad.




50Hz 3 Phase Diesel Power Silent Diesel Generator 80 kVA for Emergency Power


50Hz 3 Phase Diesel Power Silent Diesel Generator 80 kVA for Emergency Power




  50Hz 3 Phase Diesel Power Silent Diesel Generator 80 kVA for Emergency Power

50Hz 3 Phase Diesel Power Silent Diesel Generator 80 kVA for Emergency Power



Diesel Power Generator Set  GF/GFS-P  Series 
 
50Hz 3 Phase Diesel Power Silent Diesel Generator 80 kVA for Emergency Power50Hz Series Specification
Generator Set Performance Engine Specification Open Genset
Genset Model 50Hz Output Engine Model Cylinder NO Dimension Weight
50Hz Prime  Standby L*W*H (mm) KG
KVA KW KVA KW
GS-P8 8 6.5 9 7 403D-11G 3 1580*810*930 359
GS-P13 13 10 14 11 403D-15G 3 1580*810*930 370
GS-P20 20 16 23 18 404D-22G 4 1580*810*990 460
GS-P45 45 36 50 40 1103A-33TG1 3 1580*810*1150 722
GS-P60 60 48 65 52 1103A-33TG2 3 1580*810*1150 780
GS-P65 65 52 73 58 1104A-44TG1 4 1580*810*1165 800
GS-P80 80 64 88 70 1104A-44TG2 4 1760*810*1165 840
GS-P90 90 72 100 80 1104C-44TAG2 4 1760*810*1165 880
GS-P100 100 80 110 88 1006TG2A 6 2240*960*1315 905
GS-P150 150 120 165 132 1006TAG2 6 2240*960*1315 1100
GS-P180 180 144 198 158 1106C-E66TAG4 6 2345*810*1365 1300
GS-P250 250 200 275 220 1306C-E87TAG6 6 2430*960*1590 2270
GS-P300 300 240 330 264 2306A-E13TAG2 6 3280*1130*1950 3100
GS-P350 350 280 400 320 2306A-E13TAG2 6 3280*1130*1950 3500
GS-P400 400 320 450 360 2306A-E13TAG3 6 3280*1130*1950 3800
GS-P450 450 360 500 400 2506A-E15TAG1 6 3310*1180*1950 3950
GS-P500 500 400 550 440 2506A-E15TAG2 6 3310*1180*1950 4000





50Hz 3 Phase Diesel Power Silent Diesel Generator 80 kVA for Emergency Power





50Hz 3 Phase Diesel Power Silent Diesel Generator 80 kVA for Emergency Power
50Hz 3 Phase Diesel Power Silent Diesel Generator 80 kVA for Emergency Power






50Hz 3 Phase Diesel Power Silent Diesel Generator 80 kVA for Emergency Power







50Hz 3 Phase Diesel Power Silent Diesel Generator 80 kVA for Emergency Power



-------------------------------- -----------------------------------------------------After-Sale Part------------------------------------------------------------------------------------
Helpful tips on Generator Set Fault
When fault occurs during generator set running,could do primary judgement according to following tips.
Icon Indicator Light Reason Fault Analysis and Solve Method
High Water Temperature Alarm High Water Temperature Alarm When water Temperature has risen to a level higher than or equal to the sensor setting,the light is on. Normally,it is caused by lack of Water or Oil Shortage,or Overload. ----Should Automatically Shutdown Generator set Immediately.
Low Oil Pressure Alarm Low Oil Pressure Alarm When water Temperature has risen to a level higher than or equal to the sensor setting,the light is on. Normally,it is because of lack of Oil or Lubrication System Failure which caused by refueling or replacing the Oil Filter.----- When occurs this fault,should automatically shutdown generator set immediately.
Low Fuel Level Alarm Low Fuel Level Alarm When Fuel level has been detected by sensor fitted to the daily tank,the light is off. Normally,it caused by lacking of Water or Oil Shortage,or Overload.-----When occures this Fault,should automatically shutdown Generator set Immediately.
Battery Charger Fault Alarm Battery Charger Fault Alarm The Charing System has fault while engine still running,the light is off. Battery Charging System Fault Caused.---The light in on at the initial Start,when the charger reaches a certain speed,the light is off.---This Failure will not lead to Automatic Shutdown Generating Unit.
Crank Failure Alarm Crank Failure Alarm When Generator set fail three times(or six times) in arow starting,the light is on It is caused by Oil Supply System or Re-Start System Failure.
Overload or Breaker Tripping Alarm Overload or Breaker Tripping Alarm When Overloading or Short Circuit,the light is on. Tripping Circuit Breaker cause generator set load out. For this fault,it needs to load or unload some parts to eliminate short-Circuit,and then re-close the circuit Breaker.