1540kVA Mitsubishi Engine Diesel Standby/Backup Power Generator with Brushless Alternator

Get reliable standby power with our 1540kVA Mitsubishi Engine Diesel Generator. Perfect for factories and industrial facilities.
Request a Quote

PRODUCTS DETAILS

Basic Info.

Model NO.
MC
Installation Method
Fixed
Stroke
Four Stroke
Cooling Method
Water Cooling
Output Type
AC Three Phase
Speed
Low Speed
Conditions of Use
Land Use
Usage
Common Units, Standby Unit, Emergency Crew
Landuse Type of Unit
Automation Type
Excitation Mode
Static Exciter
Engine Brand
Mitsubishi/Sme Series All Range
Control Panel
Deepsea/Comap/Datakom/Delixi/Smartgen and Others
Cylinders
6-20 Cylinders
Canopy Type
Silent Sound Proof/Weather Proof/Anti-Rusted Proof
Frequency(Hz)
50Hz/60Hz
Voltage Output
400/230V, Others as Application Requested
Application
Building/Hospital/Construction/Data Center
Accessory[a]
Spare Parts Document
Diesel Generator Set
Electric Start Power Generator
Governing Type
Mech/Elec/ECU/Ecm/Adec/Hpcr
Dg Set
Emergency Diesel Generator
Diesel Powered Generator
3 Phase Generator for Sale
Certificate Available
CE, ISO, OEM Authorization etc.
Rotating Speed
1500rpm 1800rpm
Industrial Generators
Diesel Electric Generator
Transport Package
Both Standard Marine Packing or Compact Packing.
Specification
As below Spec. with details
Trademark
Mecca
Origin
China
HS Code
85021100
Production Capacity
1000/Year

Product Description

Mecca Power, as part of a Global Power Supplier initiative, provides a professional solution for the design, application and after-sales support of generators.

Strongly focused on innovation and the inherent flexibility of product design, Mecca Power has been successful in global markets with a broad and diverse range of genset power products that can operate autonomously or independently. parallel, on-site or remotely controlled.

With more than 10 years of experience in manufacturing and exporting energy products, the Mecca team will advise you on product choices. 

1540kVA Mitsubishi Engine Diesel Standby/Backup Power Generator with Brushless Alternator
1540kVA Mitsubishi Engine Diesel Standby/Backup Power Generator with Brushless Alternator
1540kVA Mitsubishi Engine Diesel Standby/Backup Power Generator with Brushless Alternator
1540kVA Mitsubishi Engine Diesel Standby/Backup Power Generator with Brushless Alternator
1540kVA Mitsubishi Engine Diesel Standby/Backup Power Generator with Brushless Alternator
1540kVA Mitsubishi Engine Diesel Standby/Backup Power Generator with Brushless Alternator 1540kVA Mitsubishi Engine Diesel Standby/Backup Power Generator with Brushless Alternator
View more products click here...
 
Powered by  Mitsubishi            50HZ 400/230 V    8-2500KVA 
Model LTP PRP Engine Fuel Cons. Cyl. Disp. Gov. Dimention Weight
KVA / KW  KVA/KW  Model Origin L/H(100%) L*W*H (MM) KGS
MC8MT 8 6.4 7 5.6 L3E IN 2 3L 1 E 1100*600*900 380
MC11MT 11 8.8 10 8 S3L2 IN 3 3L 1.3 E 1200*600*900 430
MC16.5MT 16.5 13 15 12 S4L2 IN 4.1 4L 1.8 E 1250*600*900 450
MC34MT 34 28 31 25 S4S JP 7.3 4L 3.3 E 1450*600*1000 650
MC50MT 50 40 45 36 S4K JP 10.2 4L 4.2 E 1800*800*1200 750
MC66MT 66 53 60 48 S4K-T JP 13 4L 4.2 E 1800*800*1200 750
MC100MT 100 80 90 72 S6K-T JP 19.2 6L 6.4 E 2100*850*1300 950
MC825MT 825 660  750 600  S6R2-PTAA JP 165 6L 30.0  E 4100*1400*2150 6410 
MC880MT 880 704  800 640  S12A2-PTA JP 174 12V 33.9 E 4100*1400*2150 6410 
MC1100MT 1100 880  1000 800  S12H-PTA JP 220 12V 37.1 E 4880*2000*2380 10560
MC1400MT 1400 1120  1250 1000  S12R-PTA JP 264 12V 49.0  E 4880*2000*2380 10560 
MC1540MT 1540 1232  1400 1120  S12R-PTA2 JP 284 12V 49 E 4980*2000*2380 10560
MC1650MT 1650 1320  1500 1200  S12R-PTAA2 JP 350 12V 49 E 4980*2200*2380 10660
MC1915MT 1915 1532  1750 1400  S16R-PTA JP 382 16V 65.4 E 5490*2190*2495 11410
MC2100MT 2100 1680  1875 1500  S16R-PTA2 JP 424 16V 65.4 E 5640*2170*2495 11710
MC2250MT 2250 1800  2050 1640  S16R-PTAA2 JP 452 16V 65.4 E 5920*2200*3286 13210
MC2500MT 2500 2000  2250 1800  S16R2-PTAW JP 491 16V 65.4 E 5920*2200*3286 13500
MC715SME 715 572  650 520  S6R2-PTA-C CN 140 6L 30.0  E 3770*1400*2000 6140 
MC825SME 825 660  750 600  S6R2-PTAA-C CN 165 6L 30.0  E 4100*1400*2150 6410 
MC1400SME 1400 1120  1250 1000  S12R-PTA-C CN 264 12V 49.0  E 4880*2000*2380 10560 
MC1540SME 1540 1232  1400 1120  S12R-PTA2-C CN 284 12V 49.0  E 4980*2000*2380 10560 
MC1650SME 1650 1320  1500 1200  S12R-PTAA2-C CN 350 12V 49.0  E 4980*2200*2380 10660 
MC1915SME 1915 1532  1750 1400  S16R-PTA-C CN 382 16V 65.4  E 5490*2190*2495 11410 
MC2100SME 2100 1680  1875 1500  S16R-PTA2-C CN 424 16V 65.4  E 5640*2170*2495 11710 
MC2250SME 2250 1800  2050 1640  S16R-PTAA2-C CN 452 16V 65.4  E 5920*2200*3286 13210 
Genset Main Technical Data
Genset Model MC8MT-MC2250SME
Prime Power 600kW-1640kW
Standby Power 660KW-1800kW
Frequency/Speed 50Hz/1500rpm
Standard Voltage 400V, Others as Application Requested
Phases Three phases, four wires
Dimensions(L×W×H)mm Open/Silent dimension as below list
100% Fuel Cons. (L/H) 3.9~77.6
Base Fuel tank (hour) 8~10
Alternator Specifications
Alternator Model STAMFORD TAL/PI/UCI/HCI/LVI Series
Output power 600kW-1640kW
Voltage control AVR
Number of phase 3
Power factor (Cos Phi) 0.8
Insulation Class H
Number of Wires  6
Protection 23
Altitude  ≤ 1000 m
Number of Pole  4
Exciter type AREP
Voltage regulation ±0.5%           
Totale Harmonic distortion at no load < 4 % - on load < 4 %
Bearing   Single
Coupling Direct
Alternator Data
♦ Operate either 50Hz or 60Hz. ♦Stator grease insulation covered
♦ Standard enclosure IP23, but IP44, IP55 for option ♦Rotator and excitation high polymer
♦ Insulation class H.  ♦ Resist the corruption oil and acid
♦ Shunt excitataion systems. ♦Rotator balance is in accordance with BS5625  
♦ AREP or PMG system for options.  standard 12.5
♦ Automatic voltage regulator ♦High-quality lubrication sealed long-time bearing
♦ Single bearing alternator ♦Rotator silicon steel close tight
Standard Accessories
*Auto Control Panel *Starting Motor
*Main Ciruit Breaker *Exhaust silencer
*Fuel tank *Starting battery
*Base Frame *Float battery charger
*Filter  *Flange

1540kVA Mitsubishi Engine Diesel Standby/Backup Power Generator with Brushless Alternator
1540kVA Mitsubishi Engine Diesel Standby/Backup Power Generator with Brushless Alternator 1540kVA Mitsubishi Engine Diesel Standby/Backup Power Generator with Brushless Alternator

 

Payment Terms:
By telegraphic transfer: 30% deposit on signing of sales contract; and balance 70% before dispatch. 
                                
Delivery:
Approximately 2-4 weeks upon order confirmation.

Service Guarantee:
Before Service: According to the clients' requirement and actual situation, we will furnish the technology consultation and kinds of information.  

After Service: Guarantee for one year or 1200 running hours (accord to whichever reach first) from installed date.
During the guarantee period, we will provide the free easy-damaged spare-parts for problems caused by our quality of production or raw material, except the damageable spare parts of diesel engine caused by customer's incorrect man-made operation. After checking, our company provides cost spare-parts maintenance for gensets .  


Beside genset one-stop purchasing service to world-wide customers,CKD and SKD packing service are also available according to unique request.

CKD:Complete Knock Down Generator
Generator completely knocked down into parts without assembling. 
All items from following are seperately packed without connection.
 
SKD:Semi Knock Down Generator
Partially assembled generator. 
Part of the following items you choose will be assembled.
 
Advantage:
Prompt delivery
Reduced tax to win more competition
Lower transportation fees to save cost
Localized production to win more tenders. 
Increased production to offer more job opportunity for the government

Item
 

Service
 

Option
 

Delivery Time
 
1 Engine Doosan, Mtu, Mitsubishi, SME, Volvo, 
Deutz, Yanmar, Faw, YangDong, Aoling, Yuchai, Lovol, Wandi, ect.
Marine and industry use 
Diesel, gas
2-45days
2 Alternator Stamford, Leroysomer,  Meccalte,  Marathon  and 
customer requested alternators
Medium and high voltage, 
Marine and industry use 
High IP Grade
CT Drop kits, PMG, AVR
2-15 days
3 Radiator Fast, Beworld brand
Original Radiator come with engine
Local made radiator with authorization by engine supplier
2-7days
4 Canopies Powder coated and form mounted canopy,completely break down with hings,
locks, raincap,bolts,screws, etc.
Exhaust pipe and flanges 
Standard silent type canopy package 
Denyo type canopy package 
Rental type canopy package 
Telecom type canopy package 
Super silent type canopy package 
Containerized type canopy package 
Customerized type canopy package
10days
5 Base frame Standard base or simple iron base
Anti-Vibration mountings
With/without tank, base tank volume no limited
Fuel gauges and high pressure fuel pipes
3days
6 Control system Controller: ComAp, DeepSea, Datacom, SmartGen etc.
Breaker:Delixi,ABB, Chint, etc.
Battery switch, battery charger, emergency stop botton, 
indicator, meters, CT and all wiring and harness.
Batteries and cables
Speed & lub oil & water temp sensors,
A package of standard parts for assembly
3days
7 Exhaust System Industrial and residential silencer
Flexible connects and elbow
3days
8
Others
 
Special demands  

-----------------------------------------------------------------------------------------------MAITAINENCE---------------------------------------------------------------------------------------------

General Troubleshooting            

This section lists the generating set for some common fault, the reasons for the failure and determines the            
method of fault. General operators can determine their own fault and note, maintenance it according to the            
brochure. But please contact the repairing agents when meeting a special note or not listed failure of operation.            
Please remember the following suggestions before repairing:            
- Make sure that study the failure carefully before any operation.            
- Repair with the easiest way and most commonly used method.            
- Find the exact causes of failure and completely solve the fault.      
     

1. Generator Sets            
Description of this section is for reference only. If the following failure occurs please contact the repairing agents.            
(Some models of control panel installed only parts of the following warning indicator light)
Icon Indicator Light Reason Fault Analysis
Low oil pressure
alarm
Low oil pressure
alarm
When oil pressure does not
reduce normally, the light is on.
-General because of a lack of oil or lubrication
system failure caused by (refueling or replacing
the oil filter)
-When occurs this fault should automatically
shutdown generator sets immediately.
High water
temperature
alarm
High water
temperature
alarm
When the water temperature
has risen to a level higher than
or equal to the sensor setting,
the light is on.
-General because of a lack of water or oil
shortage, or overload.
-When occurs this fault should automatically
shutdown generator sets immediately.
Low fuel level
alarm
Low fuel level
alarm
When a fuel level has been
detected by the sensor fitted to
the daily tank, the light is on.
-General because of a lack of water or oil
shortage, or overload.
-When occurs this fault should automatically
shutdown generator sets immediately.
Battery charger
fault alarm
Battery charger
fault alarm
If the charging system has fault,
when engine running, the light is
off.
-Battery charging system fault caused.
-The light is on at the initial start, when the
charger reaches a certain speed, the light is off.
-This failure will not lead to automatic shutdown
generating units.
Crank failure
alarm
Crank failure
alarm
When the generator set failed
three times (or six times) in a
row starting, the light is on.
-Oil supply system or re-start the system failure
caused.
Overload or
breaker tripping
alarm
Overload or
breaker tripping
alarm
When overloading or Short
circuit, the light is on. Tripping
circuit breakers cause generator
set load out.
-In this fault, it need to load or unload some parts
to eliminate short-circuit, and then re-close the
circuit breaker.

Introduction of Maintenance grade(Interval) for the generator set 
A Level Maintenance Interval (Daily Maintenance)
1. Check Daily Report of Genset .
2. Check fuel level and coolant level. 
3. Check alternator for cracks or other damage, and the condition of the belts must be checked, flab or 
other damage.
4. Check the Air filter. The air filter should be replaced when necessary .
5. Release fuel tank and fuel filter's water and sediment.
6. Check the water cooling filter.
7. Check starting battery and electrolyte, add electrolyte when necessary. 
8. Check the starter, check noisy defect.
9. Use air syringe cleaner to clean the water tank, coolant system and cooled fin net.
B Level Maintenance Interval (Less than 400 hours)
1. Repeatedly check A Level Daily Maintenance steps.
2. After operating 100 to 250 hours, replace the fuel filter. All the fuel filters should not be cleaned, it 
should be replaced. 100 to 250 hours is just flexible time, actually it must be according to the practice 
and real fact. 
3. After operating 200 to 250 hours, replace the oil & oil filter. All the lube oil must fit up to the CF 
Grade of American Petroleum Institute.
4. After operating 300 to 400 hours, replace the air filter. The air filter can be cleaned with air syringe, or 
it can be replaced. The replacement must be according to the environment and real fact.
5. Replace the cooling system and add coolant concentration.
6. Clean the crankshaft and inlet, outlet air- filter net. 
C Level Maintenance Interval (2000-3000 hours), Please do as follows:
1. Repeatedly check A and B Level Daily Maintenance steps.
2. Remove the tap of valve, clean and wash oil dirt and sludge.
3. Fasten snails from each part (including running parts and fixed parts)
4. Clean and wash the crankcase, oil sludge, steel scraps and sediment with engine.
5. Check wearing of the engine turbo, clean and wash accumulation of carbon, adjust it when necessary.
6. Check and adjust valve clearance.
7. Check PT pump, quality of injection, adjust injection process, adjust it when necessary.
8. Check and adjust the tension of fan belt and water pump belt, adjust and replace it when necessary; 
clean and wash water tank radiator fins, then check the using capability of thermostat.
Current Repair (D Level Maintenance)(3000-4000 hours)
1. Check valve, valve seat and other wearing, repair or change it when necessary.
2. Check P pump, quality of injection, repair and adjust it when necessary.
3. Check and adjust connecting rod and fastening twisting torque.
4. Check and adjust valve clearance.
5. Check the trip of injector.
6. Check and adjust tension of fan and generating belt.
7. Clean and wash accumulation of carbon in inlet pipes.
8. Clean and wash the core of air cooler.
9. Clean and wash the whole oil lubrication system.
10. Clean and wash room of rocker arm, oil sludge in the sump and Metal scrap-iron.
Medium Repair (6000-8000 hours)
1. Including the items of minor repair.
2. Disassemble generator(except crankshaft)
3. Check the easy worn spare parts in pitman shaft system, gas distribution system, lubrication system, 
cooling system of cylinder, Piston, Intake and exhaust valve, replace them when necessary.
4. Check fuel supplying system, adjust oil pump and injector.
5. Repair and test the alternator, clean oil-sediment and lubricate the bearing of alternator.
Overhaul (9000-15000hours)
1. Including the items of intermediate repair.
2. Disassemble all the parts in the generator.
3. Replace cylinder, piston, piston loop, big and small bearing bushes, trusting pad of crankshaft, intake 
and exhaust valve, a whole set of tools for generator repair 
4. Adjust oil pump, injector and replace pump core, injector
5. Replace a whole set of repair tools for turbo charger and a repair set for water pump.
6. Adjust the parts of connecting rod, crankshaft and generator body,repair or replace them when necessary

Contact us

Please feel free to give your inquiry in the form below We will reply you in 24 hours