Silent Diesel Power Electric Generator 25 Kilowatt Generator with ATS Automatic Transfer

Get reliable power backup with our Silent Diesel Power Electric Generator 25 Kilowatt Generator with ATS Automatic Transfer. Factory direct prices.
Request a Quote

PRODUCTS DETAILS

Basic Info.

Model NO.
GF/GFS-C25KW
Output Type
AC Three Phase
Speed
Speed
Conditions of Use
Land Use
Usage
Common Units, Standby Unit, Emergency Crew
Landuse Type of Unit
Automation Type
Excitation Mode
AC Rotating Exciter
Engine
Cummins
Engine Model
4BTA3.9-G2
Alternator
Stamford/ Stamford Copy
Model
Open Type/Silent Type/Trailer Type/Container Type
Fuel Tank
8 Hours Base Fuel Tank
Controller
Comap/Smartgen
Alternative
Installing with ATS
Color
Depends
dB Noise Level
75dB at 7 Meters
Frequency
50Hz/60Hz
Voltage
380V/220V 3 Phase
Transport Package
Wooden Package
Specification
6CBM
Trademark
Gspark
Origin
Fujian
HS Code
8502
Production Capacity
2500/Month

Product Description

Brief introduction:  Genspark Equipment Co.,Ltd mainly Supply Diesel Generator Set and Gas Generator set,including in Famous brands,Deutz,Doosan,MTU,ShangHai Diesel,YangDong etc,raning from 10KW-2000KW Outputs.Having Open type,Silent type,Container type and trailer type generator models.

With more than 10 years experience on supplying Generator sets,We always offer Most Suitable Products for Customers Abroad.




Silent Diesel Power Electric Generator 25 Kilowatt Generator with ATS Automatic Transfer


Silent Diesel Power Electric Generator 25 Kilowatt Generator with ATS Automatic Transfer




  Silent Diesel Power Electric Generator 25 Kilowatt Generator with ATS Automatic Transfer

Silent Diesel Power Electric Generator 25 Kilowatt Generator with ATS Automatic Transfer



  Diesel Power Generator Set  GF/GFS-C  Series
 
Silent Diesel Power Electric Generator 25 Kilowatt Generator with ATS Automatic Transfer50Hz diesel Generator Series powered by Cummins
 
Generator Set Performance Engine Specification Open Genset Soundproof type
Genset Model 50Hz Output Engine Model Power(Kw) Fuel Comsuption(100% Load) Dimension Weight Dimension
50Hz Prime  Standby KW L/H L*W*H (mm) KG L*W*H(mm)
KVA KW KVA KW
G/GS-C350 350 280 387.5 310 NTA855-G4 318 65 3000*1100*1800 3050 3500*1300*2000
G/GS-C375 375 300 412.5 330 NTAA855-G7 343 69.9 3000*1100*1800 3100 3500*1300*2000
G/GS-C409     450 360 NTAA855-G7A 377 76.89 3000*1100*1800 3300 3500*1300*2000
G/GS-C450 450 360 500 400 KTA19-G3 403 83.9 3450*1300*1800 4000 3800*1400*2100
G/GS-C500 500 400 550 440 KTA19-G3A 448 90 3450*1300*2000 4200 4200*1400*2200
G/GS-C500 500 400 550 440 KTA19-G4 448 93.2 3850*1300*2000 4300 4200*1400*2200
G/GS-C525 525 420 631.2 505 KTAA19-G5 470 97.9 3850*1300*2000 4600 4500*1400*2200
G/GS-C625     687.5 550 KTAA19-G7 560 116.5 3850*1300*2000 4600 4500*1400*2200
G/GS-C590     650 520 KTA19-G8 575 116.5 3850*1300*2000 4600 4500*1400*2200
G/GS-C614     675 540 KTA38-GA 560 130 4500*1800*2450 6950 5500*2000*2900
G/GS-C625 625 500 687.5 550 KTA38-G 560 116.5 4500*1800*2450 6950 ISO20GP
G/GS-C750 750 600 825 660 KTA38-G2 664 139.8 4500*1800*2450 7050 ISO20GP
G/GS-C800 800 640 887.5 710 KTA38-G2B 711 170 4500*1800*2450 7200 ISO20GP
G/GS-C910 910 728 1001 800 KTA38-G2A 813 170 4500*1800*2450 7200 ISO20GP
G/GS-C1000 1000 800 1100 880 KTA38-G5 880 186.4 4800*1950*2400 7900 ISO20GP
G/GS-C1136     1250 1000 KTA38-G9 1000 196 5800*2010*2500 8500 ISO20GP
G/GS-C1200 1200 960 1320 1056 QSK38-G5 1063 220 5800*2010*2500 9000 ISO20GP
G/GS-C1250 1250 1000 1375 1100 KTA38-G3 1097 233 5800*2010*2500 9000 ISO40GP
G/GS-C1375 1375 1100 1513 1210 KTA50-G8 1200 256.3 5800*2010*2500 9000 ISO40GP
G/GS-C1450 1450 1160 1625 1300 KTA50-GS8 1287 273 5800*2010*2500 9000 ISO40GP
G/GS-C1650 1650 1320 1815 1452 QSK50-G7     5800*2250*2660 12700 ISO40GP
G/GS-C2000 2000 1600 2200 1760 QSK60-G4     2800*2250*2660 14500 ISO40GP
G/GS-C2250 2250 1800 2500 2000 QSK60-G13     6150*2580*2700 14500 ISO40GP



Silent Diesel Power Electric Generator 25 Kilowatt Generator with ATS Automatic Transfer





Silent Diesel Power Electric Generator 25 Kilowatt Generator with ATS Automatic Transfer
Silent Diesel Power Electric Generator 25 Kilowatt Generator with ATS Automatic Transfer






Silent Diesel Power Electric Generator 25 Kilowatt Generator with ATS Automatic Transfer







Silent Diesel Power Electric Generator 25 Kilowatt Generator with ATS Automatic Transfer



-------------------------------- -----------------------------------------------------After-Sale Part------------------------------------------------------------------------------------
Helpful tips on Generator Set Fault
When fault occurs during generator set running,could do primary judgement according to following tips.
Icon Indicator Light Reason Fault Analysis and Solve Method
High Water Temperature Alarm High Water Temperature Alarm When water Temperature has risen to a level higher than or equal to the sensor setting,the light is on. Normally,it is caused by lack of Water or Oil Shortage,or Overload. ----Should Automatically Shutdown Generator set Immediately.
Low Oil Pressure Alarm Low Oil Pressure Alarm When water Temperature has risen to a level higher than or equal to the sensor setting,the light is on. Normally,it is because of lack of Oil or Lubrication System Failure which caused by refueling or replacing the Oil Filter.----- When occurs this fault,should automatically shutdown generator set immediately.
Low Fuel Level Alarm Low Fuel Level Alarm When Fuel level has been detected by sensor fitted to the daily tank,the light is off. Normally,it caused by lacking of Water or Oil Shortage,or Overload.-----When occures this Fault,should automatically shutdown Generator set Immediately.
Battery Charger Fault Alarm Battery Charger Fault Alarm The Charing System has fault while engine still running,the light is off. Battery Charging System Fault Caused.---The light in on at the initial Start,when the charger reaches a certain speed,the light is off.---This Failure will not lead to Automatic Shutdown Generating Unit.
Crank Failure Alarm Crank Failure Alarm When Generator set fail three times(or six times) in arow starting,the light is on It is caused by Oil Supply System or Re-Start System Failure.
Overload or Breaker Tripping Alarm Overload or Breaker Tripping Alarm When Overloading or Short Circuit,the light is on. Tripping Circuit Breaker cause generator set load out. For this fault,it needs to load or unload some parts to eliminate short-Circuit,and then re-close the circuit Breaker.


 Welcome your further contact and sending inquiry!

















 

 

 



 

Contact us

Please feel free to give your inquiry in the form below We will reply you in 24 hours