Basic Info.
Model NO.
005
Installation Method
Fixed
Stroke
Four Stroke
Cooling Method
Air Cooled
Output Type
AC Three Phase
Speed
Speed
Conditions of Use
Land Use
Usage
Common Units, Standby Unit, Emergency Crew
Landuse Type of Unit
Low Noise Automation Type
Excitation Mode
AC Rotating Exciter
Transport Package
Pack
Specification
3KW/5KW/10KW/20KW
Trademark
YC
Origin
Jiangsu
HS Code
8502110000
Production Capacity
50000
Packaging & Delivery
Package Size
107.00cm * 73.00cm * 79.00cm
Package Gross Weight
500.000kg
Product Description
There are several benefits of using a generator for cold room. First, diesel generator provide more power. This is because diesel has a higher energy value. Secondly, because most of the cold room is used to store foods, once the cold room is powered off, the condensing units of the entire cold room will not be able to operate due to power failure. So in order to cold room can operate normally even in the case of power failure, it is very necessary to equip a diesel generator for your cold room!
The backup power supply is necessary for the cold storage room to remain functional to avoid the deterioration of high-value-added goods such as vegetables and food stored in the room after a long period of power failure.
Cold rooms with generators are suitable for places without proper power. Generally, the conventional type of cold room cannot operate in a generator. This is mainly because it needs a lot of power. However, our cold rooms operate at low power. Hence it is possible to operate our cold rooms with generators.
With the solar system, we can achieve 24/7 uninterrupted power supply, making it possible to operate cold storage at the lowest cost.
In places far away from the grid, matching generator systems and solar systems can realize the low-cost operation of cold storage.
Generators can be divided into two types: air-cooled and water-cooled. We provide a variety of options for different cold storage sizes.
As for how to choose a generator for cold storage, we will have a professional engineering team design and select a suitable generator model according to the project situation.
FAQ
The backup power supply is necessary for the cold storage room to remain functional to avoid the deterioration of high-value-added goods such as vegetables and food stored in the room after a long period of power failure.
Cold rooms with generators are suitable for places without proper power. Generally, the conventional type of cold room cannot operate in a generator. This is mainly because it needs a lot of power. However, our cold rooms operate at low power. Hence it is possible to operate our cold rooms with generators.
With the solar system, we can achieve 24/7 uninterrupted power supply, making it possible to operate cold storage at the lowest cost.
In places far away from the grid, matching generator systems and solar systems can realize the low-cost operation of cold storage.
Generators can be divided into two types: air-cooled and water-cooled. We provide a variety of options for different cold storage sizes.
As for how to choose a generator for cold storage, we will have a professional engineering team design and select a suitable generator model according to the project situation.
Open-frame diesel generator | |||||||||
Model | DG2500 | DG3000 | DG5000E | DG6000E | DG7000E | DG8000E | DG4500EI-Inverter generator | DG12000E | DG15000E |
Rated frequency (HZ) | 50/60 | 50/60 | 50/60 | 50/60 | 50/60 | 50/60 | 50/60 | 50/60 | 50/60 |
Rated Output (kVA/KW) | 1.8/2 | 2.8/3 | 4.2/4.6 | 4.6/5 | 5/5.5 | 6/6.5 | 3 | 8.5/9 | 11/12 |
Max. Output (kVA/KW) | 2/2.2 | 3/3.3 | 4.6/5 | 5/5.5 | 5.5/6 | 6.5/7 | 3.3 | 9/9.5 | 10/11 |
Copper of alternator | 100% | 100% | 100% | 100% | 100% | 100% | 100% | 100% | 100% |
Rated voltage (V) | According to country | According to country | According to country | According to country | According to country | According to country | According to country | According to country | According to country |
DC output (V) | 12/8.3A | 12/8.3A | 12/8.3A | 12/8.3A | 12/8.3A | 12/8.3A | 12/8.3A | 12/8.3A | 12/8.3A |
Rated rotation speed (r/min) | 3000/3600 | 3000/3600 | 3000/3600 | 3000/3600 | 3000/3600 | 3000/3600 | 3000/3600 | 3000/3600 | 3000/3600 |
Phase | Single Phase | Single Phase | Single Phase | Single Phase | Single Phase | Single Phase | Single Phase | Single Phase | Single Phase |
Power factor (cos) | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 |
Engine model | 170F | 178F | 186F | 186FA | 188FA | 192FB | 178F | 2V86F | 2V88F |
Engine type | single-cylinder | single-cylinder | single-cylinder | single-cylinder | single-cylinder | single-cylinder | two-cylinder | two-cylinder | two-cylinder |
Bore×Stroke(mm) | 70*55 | 78*62 | 86*70 | 86*72 | 88*75 | 92*75 | 78*62 | 86*72 | 88*75 |
Combustion System | Direct Injection | Direct Injection | Direct Injection | Direct Injection | Direct Injection | Direct Injection | Direct Injection | Direct Injection | Direct Injection |
Fuel | Diesel | Diesel | Diesel | Diesel | Diesel | Diesel | Diesel | Diesel | Diesel |
Displacement, ml³ | 211cc | 296cc | 406cc | 418cc | 456cc | 498cc | 296cc | ||
Starting system | Recoil,(Electric add $54) | Recoil,(Electric add $54) | Electric | Electric | Electric | Electric | Electric | Electric | Electric |
Lubrication Oil Volume (L) | 0.75 | 1.1 | 1.65 | 1.65 | 1.65 | 1.65 | 1.65 | ||
Fuel(L) | 0# or -10# light diesel oil | 0# or -10# light diesel oil | 0# or -10# light diesel oil | 0# or -10# light diesel oil | 0# or -10# light diesel oil | 0# or -10# light diesel oil | 0# or -10# light diesel oil | 0# or -10# light diesel oil | 0# or -10# light diesel oil |
Fuel tank capacity (L) | 12.5 | 12.5 | 12.5 | 12.5 | 12.5 | 12.5 | 12.5 | 30 | 30 |
Fuel consumption (g/KW.h) | ≤295 | ≤295 | ≤285 | ≤280 | ≤285 | ≤280 | ≤295 | ≤268 | ≤268 |
Continuous running time | 17/14.5 | 9.7/9 | 7.1/6.5 | 6.5/6 | 6.5/6 | 6.5/6 | 9.2 | 9.4/8.4 | 7.4/6.3 |
Cooling system | Air-cooled | Air-cooled | Air-cooled | Air-cooled | Air-cooled | Air-cooled | Air-cooled | Air-cooled | Air cooled |
Noise level (7m, dB) | 80-85 | 80-85 | 80-85 | 80-85 | 80-85 | 80-85 | 80-85 | 85 | 85 |
Overall dimensions, L*W*H, mm | 640*470*510 | 670*470*560 | 700*470*600 | 700*470*600 | 730*470*600 | 730*470*600 | 670*470*560 | 850*630*680 | 880*680*750 |
Net weight / Gross weight (kg) | 52 | 64 | 84 | 84 | 85 | 85 | 62 | 480 | 238 |
Loading qty (20GP) | 150(20GP) | 130(20GP) | 102(20GP) | 102(20GP) | 102(20GP) | 102(20GP) | 130(20GP) | 26(20GP) | 24(20GP) |
Warranty(Year) | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 |
Standard features | CE, GS certificated by TUV Rheinland,ISO9001 |
Silent frame diesel generator | ||||||||
Model | DG3500SE | DG5500SE | DG6500SE | DG6500SE-N | DG7500SE | DG8500SE | DG12000SE | DG15000SE |
Rated frequency (HZ) | 50/60 | 50/60 | 50/60 | 50/60 | 50/60 | 50/60 | 50/60 | 50/60 |
Rated Output (kVA/KW) | 2.8/3 | 4.2/4.6 | 4.6/5 | 4.2/4.6 | 5/5.5 | 6/6.5 | 8.5/9 | 11/12 |
Max. Output (kVA/KW) | 3/3.3 | 4.6/5 | 5/5.5 | 4.6/5 | 5.5/6 | 6.5/7 | 9/9.5 | 10/11 |
Copper of alternator | 100% | 100% | 100% | 100% | 100% | 100% | 100% | 100% |
Rated voltage (V) | According to country | According to country | According to country | According to country | According to country | According to country | According to country | According to country |
DC output (V) | 12/8.3A | 12/8.3A | 12/8.3A | 12/8.3A | 12/8.3A | 12/8.3A | 12/8.3A | 12/8.3A |
Rated rotation speed (r/min) | 3000/3600 | 3000/3600 | 3000/3600 | 3000/3600 | 3000/3600 | 3000/3600 | 3000/3600 | 3000/3600 |
Phase | Single Phase | Single Phase | Single Phase | Single Phase | Single Phase | Single Phase | Single Phase | Single Phase |
Power factor (cos) | 1 | 1 | 1 | 1 | 1 | 1 | 1 | |
Engine model | 178F | 186F | 186FA | 186FA | 188FA | 192FB | 2V86F | 2V88F |
Engine type | single-cylinder | single-cylinder | single-cylinder | single-cylinder | single-cylinder | single-cylinder | two-cylinder | two-cylinder |
Bore×Stroke(mm) | 78*62 | 86*70 | 86*72 | 86*72 | 88*75 | 92*75 | 86*72 | 88*75 |
Combustion System | Direct Injection | Direct Injection | Direct Injection | Direct Injection | Direct Injection | Direct Injection | Direct Injection | Direct Injection |
Fuel | Diesel | Diesel | Diesel | Diesel | Diesel | Diesel | Diesel | Diesel |
Displacement, ml³ | 296cc | 406cc | 418cc | 418cc | 456cc | 498cc | ||
Starting system | Electric | Electric | Electric | Electric | Electric | Electric | Electric | Electric |
Lubrication Oil Volume (L) | 1.1 | 1.65 | 1.65 | 1.65 | 1.65 | 1.65 | ||
Fuel(L) | 0# or -10# light diesel oil | 0# or -11# light diesel oil | 0# or -12# light diesel oil | 0# or -13# light diesel oil | 0# or -14# light diesel oil | 0# or -15# light diesel oil | 0# or -16# light diesel oil | 0# or -17# light diesel oil |
Fuel tank capacity (L) | 16 | 16 | 16 | 12.5 | 16 | 16 | ||
Fuel consumption (g/KW.h) | ≤295 | ≤285 | ≤280 | ≤280 | ≤285 | ≤280 | ≤268 | ≤268 |
Continuous running time | 13/11.8 | 10.2/9.3 | 8.5/7.8 | 9.3/8.5 | 8.5/7.8 | 8.5/7.8 | 9.4/8.4 | 7.4/6.3 |
Cooling system | Air-cooled | Air-cooled | Air-cooled | Air-cooled | Air-cooled | Air-cooled | Air-cooled | Air-cooled |
Noise level (7m, dB) | 68-72 | 68-72 | 68-72 | 68-72 | 68-72 | 68-72 | 68-72 | 68-72 |
Overall dimensions, L*W*H, mm | 840*525*680 | 925*525*680 | 925*525*680 | 800*550*700 | 935*525*680 | 935*525*680 | 1200*725*805 | 1200*750*850 |
Net weight / Gross weight (kg) | 136 | 155 | 155 | 163 | 170 | 175 | 220 | 365 |
Loading qty (20GP) | 72(20GP) | 72(20GP) | 72(20GP) | 72(20GP) | 72(20GP) | 72(20GP) | 40(20GP) | 51(20GP) |
Warranty(Year) | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 |
Standard features | CE, GS certificated by TUV Rheinland, ISO9001 |
FAQ
1:Why equip the cold room with a diesel generator?
There are several benefits of using a generator for cold room. First, diesel generators provide more power. This is because diesel has a higher energy value. Secondly, because most of the cold room is used to store foods, once the cold room is powered off, the condensing equipment of the entire cold room will not be able to operate due to power failure. So in order to cold room can operate normally even in the case of power failure, it is very necessary to equip a diesel generator for your cold room!
2:Can cold room size be customized?
Yes, the cold room size depends on you. For example, 3*3*2.5m, 4*4*2.5m, 10*5*3m cold room size is usually used.
3: Why does other suppliers price lower than us?
The environmentally friendly PU material we use, the density is 44kg/m3. What's more, original new Biitzer compressor ensures high efficiency saving at least 20% annual energy loss.
4: How to classify the PU panel fireproofing?
There have four types: A(Non-inflammable), B1(Difficult to burn), B2(Combustible), B3(Easy to burn).
5: How to identify the cold room door' s quality?
The steel, hardware, gasket, heater, lock, etc, all decide the quality. And we use 0.6mm color plate, coolmax hinges, etc.