Basic Info.
Model NO.
220kVA
Output Type
DC
Speed
Speed
Conditions of Use
Land Use
Usage
Common Units, Standby Unit, Emergency Crew
Landuse Type of Unit
Automation Type
Excitation Mode
Static Exciter
Voltage, Frequency
400/230 V, 50 Hz
Power Factor
0.8
Phases
3
Regulation Class
ISO8528-5 G2
Transport Package
Moisture-Proof Film
Specification
40KW-50KVA
Trademark
WEICHAI
Origin
China
Production Capacity
5000 Sets Per Month
Product Description
Model: WEICHAI-PRP160KW-220KVA
Gen-set specifications | |
Model | WPG220*8 |
Standby Rating kVA/kWe | 220/176 |
Prime Rating kVA/kWe | 200/160 |
Voltage V | 400 |
Frequency Hz | 50 |
Power Factor | 0.8(lagging) |
No. of Phases | 3 |
Fuel consumption@25%/ 50% / 75%(L/h) | 13.53 / 22.54 / 31.47 |
Fuel consumption@100% / 110%(L/h) | 41.51 / 45.43 |
Sound@1m(dB·(A)) | Open ≤ 105; Silence ≤ 85 |
Ambient temp(ºC) | -10~45 |
Gen-set regulation class | ISO8528-5 G2 |
Steady-state voltage deviation | ≤±2.5% |
Transient voltage deviation (100%sudden power decrease/increase) | ≤+25% ;≤-20% |
Steady-state frequency band | ≤1.5% |
Transient frequency deviation from rated frequency (100%sudden power decrease/increase) | ≤+12%;≤-10% |
Standard Features | |||
♦ Electronic governor | ♦DC24 Electric starter | ♦ Deep-sea DSE6120 MKIII | |
♦ Closed water-cooled | ♦ IP23 | ♦H type insulation | |
♦ Air filter | ♦ Muffler | ♦ Circuit Breaker | |
♦Starting batteries | ♦ with connective wires | ♦ Radiator | |
♦Oil Drain Valve | ♦Forklift Groove | ♦Shock Absorber | |
♦ Color | Weichai blue ( F)/beige canopy and black chassis (L) | ||
♦ Packaging | Packing case (F)/ Wound film packing(L) |
Options | |||
Voltage380V/415V | Voltage 440V/480V | Single Voltage 220V/230V | |
Automatic Transfer Switch | Automatic Parallel system | PMG/AREP | |
Engine Heater (water) | Engine Heater (air inlet) | Alternator heater | |
External fuel tank(1000L/1500L) |
Engine |
- Weichai WP10 series, 6 cylinder, in-line 4 stroke, radiator cooled engine
- Well-designed air handling system with
- Dry type, Replaceable paper element air cleaner with restriction indicator
- Air to air after cooling
- Optimized turbocharger for increased altitude capabilities
- High efficiency, large heat area intercooler, reduce the air temperature after the intercooler
- Fuel system with A1 class electronic governing
- Electrical starter motor with soft start engagement feature
- Intelligent fuel injection technology to start fast guarantee
- Battery charging alternator
- 1 x 12 V DC batteries
Alternator |
- Brushless type, Screen protected, Revolving field, Self excited alternator conforming to IS/IEC 60034-1
- Best in class efficiency
- Steel casing
- Compact design with sealed bearings for longer life and lesser maintenance
- IP23 standard protection level
- Impregnation on all wound components for better mechanical strength
Control Module Specifications |
The Deep-sea DSE 6120 MKIII is an Auto Mains Failure Control Module
- Back-lit LCD display
- 3 Phase generator and 3 Phase Mains monitoring
- Monitoring speed, frequency, voltage, current, oil pressure, coolant temperature and fuel level
- Display warning, shutdown and engine status information
- Hours counter provides accurate information for monitoring and maintenance
Engine specifications | ||
Make | WEICHAI | |
Mode | WP10D200E200 | |
Rated Speed r/min | 1500 | |
Prime Power kW | 182 | |
Cooling | Liquid cooled | |
Governor | Electronic governor | |
Aspiration | TA | |
No. of cylinders | 6, in-line | |
Bore (mm) x Stroke (mm) | 126x130 | |
Displacement (L) | 9.726 | |
Starting system | 24VDC Electrical | |
Total lubrication system capacity (L) | 30 | |
Total coolant capacity (L) | 42 | |
Cooling fan airflow(m³/min) | 415 | |
Exhaust Temperature (°C) | ≤600 | |
Combustion air flow @ PRP (m³/min) | 13.2 | |
Exhaust back pressure (mBar) | ≤60 | |
Radiator design temperature(ºC) | 50 |
Alternator specifications | |
Make | WEICHAI; LEROY-SOMER |
Alternator Frame | WHA-200-4/0.4; TAL A44 M |
Exciter Type | Self-excitation |
Enclosure | IP23 |
Voltage regulation | ≤±1% |
Class of Insulation | H |
Winding Pitch | 2/3 |
Rotor | Single bearing |
Remarks |
Prime power(PRP)
Prime power is defined as being the maximum power which a generating set is capable of delivering continuously while supplying a available electrical load when operated for an unlimited number of hours per year under the agreed operating conditions with the maintenance intervals and procedures being carried out as prescribed by the manufactures.
The permissible average power output, over 24h of operation shall not exceed 70% of the PRP unless otherwise agreed by the RIC engine manufacturer.
Emergency standby power(ESP)
Emergency standby power is defined as the maximum power available during a available electrical power sequence, under the stated operating conditions, for which a generating set is capable of delivering in the event of a utility power outage or under test conditions for up to 200h of operation per year with the with the maintenance intervals and procedures being carried out as prescribed by the manufactures.
The permissible average power output, over 24h of operation shall not exceed 70% of the ESP unless otherwise agreed by the RIC engine manufacturer.
Standard operating environment: ambient temperature is 5ºC~40ºC,the altitude is less than 1000m,the relative humidity is less than 90%(25ºC),and there is no dust, sand dust, salt fog, mold, condensation environment, etc.
If the operating environment exceeds the above requirements, please contact the factory and consult.
Prime power is defined as being the maximum power which a generating set is capable of delivering continuously while supplying a available electrical load when operated for an unlimited number of hours per year under the agreed operating conditions with the maintenance intervals and procedures being carried out as prescribed by the manufactures.
The permissible average power output, over 24h of operation shall not exceed 70% of the PRP unless otherwise agreed by the RIC engine manufacturer.
Emergency standby power(ESP)
Emergency standby power is defined as the maximum power available during a available electrical power sequence, under the stated operating conditions, for which a generating set is capable of delivering in the event of a utility power outage or under test conditions for up to 200h of operation per year with the with the maintenance intervals and procedures being carried out as prescribed by the manufactures.
The permissible average power output, over 24h of operation shall not exceed 70% of the ESP unless otherwise agreed by the RIC engine manufacturer.
Standard Conditions |
If the operating environment exceeds the above requirements, please contact the factory and consult.
Typical Genset Dimensions | ||||||
Genset Model | Prime Rating (kVA) | Length A(mm) | Width B(mm) | Height C(mm) | Wet Weight* (kg) | Standard Fuel tank Capacity (L) |
WPG220F8 | 200 | 2999 | 1170 | 1920 | 2370 | 420 |
WPG220L8 | 200 | 3900 | 1350 | 2050 | 3090 | 560 |
Open genset Enclosed genset
Beijing Xinda Creation Machinery Equipment Co., Ltd. Specialized in production and sales of diesel generator sets, reefer container generator, mobile lighting tower, solar suveilliance system. Also providing Hydraulic Hammer/Breaker.
FAQ
1.Q :What's the MOQ. Can I get a sample of free?
A : MOQ, according to the actual situation.
We can offer a sample of free. Please, friendly bear the shipping cost.
2.Q : When can i get the quotation?
A : We usually quote within 24 hours after getting your detailed requirements, like size, quantity, etc.
3.Q : What is your payments terms?
A : We can accept 30% deposit, 70% balance to be against the BL copy or by LC, or other payment terms.