Basic Info.
Model NO.
CM300C15N
Standard
Standard
Natural Gas Engine Model
Cummin X15h-G380
Alternator Model
Kwise
Rated Volt
400V/230V
Rated Frequency
50/60Hz
Power Factor
0.8
Rated Speed
1000rpm/1200rpm
No. of Cylinders
6
Cylinder Bore
137mm
Piston Stroke
169mm
Displacement
15L
Exhaust Temp Before Turbo
Less Than 600ºC
Lubricating Type
Press and Spray Lubrication
Cooling Type
Water Cooling
Start Type
Motor Start
Transport Package
Wooden Box
Trademark
CUSUNMACH
Origin
China
HS Code
85022000
Production Capacity
3000 Sets Per Year
Product Description
Main structure of the generator set
Natural gas generator sets include natural gas-fueled reciprocating internal combustion engines, alternators, electrical parts, control devices, cooling systems, lubrication systems, exhaust systems, fuel systems, and auxiliary equipment. Except for the exhaust pipe and silencer of the exhaust system, they are mounted on a steel chassis. The generator set is a fixed permanent installed generator set. The steel underframe is mounted to the concrete foundation.
The basic structure of the gas engine
Cummin is the leading brand of engine over the world. We use an original engine manufactured by an authorized Cummin China factory in the USA as a power source for a generator set. The Cummin engine has the characteristics of low gas consumption, low exhaust temperature, great reliability and low maintaining price. The main structure of Cummin engine is high-strength double-walled, improved wide body, significantly increasing the reliability and durability of the engine. The four-valve design effectively increases charging efficiency.
2.4 Alternator
The brushless constant-voltage synchronous alternators are of the self-excited type with an electronic voltage regulator integrated in the excitation system. They are used as main or standby units in land based power installations and for ships' electrical systems and can be driven by internal combustion engines or gas, steam and water turbines and electric motors.
Structure:
The alternator comprises the main machine exciter and excitation system. The main machine is of revolving magnetic field with cylindrical rotor and damper winding. The exciter is revolving armature machine. The exciter power is supplied to the rotor of the main machine via rotating rectifiers.
2.5 Genset controller
The control panel can detect the current, voltage, speed, frequency, power, engine cooling water temperature, engine oil pressure, exhaust temperature, number of starts, running time, etc. of the unit. The screen also designed a variety of necessary protections for the generator set to ensure safe and stable operation of the unit. The main protections include high water temperature, low oil pressure, overspeed, high temperature, over voltage, under voltage and low frequency. The control panel provides DC power switch, emergency stop button, and unit fault alarm indication.
The controller is an easy-to-use control unit containing all necessary functions for protection and control of a genset. It can be used as a single unit for one genset, or it can be connected in a complete power management system with up to 32 controllers for synchronising projects, island or parallel to the mains. The power management system handles the load sharing between gensets and the load-dependent start and stop. The controller contains all necessary 3-phase measuring circuits, and all values and alarms are presented on the sun proof LCD display.
Parameter table
Natural gas generator sets include natural gas-fueled reciprocating internal combustion engines, alternators, electrical parts, control devices, cooling systems, lubrication systems, exhaust systems, fuel systems, and auxiliary equipment. Except for the exhaust pipe and silencer of the exhaust system, they are mounted on a steel chassis. The generator set is a fixed permanent installed generator set. The steel underframe is mounted to the concrete foundation.
The basic structure of the gas engine
Cummin is the leading brand of engine over the world. We use an original engine manufactured by an authorized Cummin China factory in the USA as a power source for a generator set. The Cummin engine has the characteristics of low gas consumption, low exhaust temperature, great reliability and low maintaining price. The main structure of Cummin engine is high-strength double-walled, improved wide body, significantly increasing the reliability and durability of the engine. The four-valve design effectively increases charging efficiency.
2.4 Alternator
The brushless constant-voltage synchronous alternators are of the self-excited type with an electronic voltage regulator integrated in the excitation system. They are used as main or standby units in land based power installations and for ships' electrical systems and can be driven by internal combustion engines or gas, steam and water turbines and electric motors.
Structure:
The alternator comprises the main machine exciter and excitation system. The main machine is of revolving magnetic field with cylindrical rotor and damper winding. The exciter is revolving armature machine. The exciter power is supplied to the rotor of the main machine via rotating rectifiers.
2.5 Genset controller
The control panel can detect the current, voltage, speed, frequency, power, engine cooling water temperature, engine oil pressure, exhaust temperature, number of starts, running time, etc. of the unit. The screen also designed a variety of necessary protections for the generator set to ensure safe and stable operation of the unit. The main protections include high water temperature, low oil pressure, overspeed, high temperature, over voltage, under voltage and low frequency. The control panel provides DC power switch, emergency stop button, and unit fault alarm indication.
The controller is an easy-to-use control unit containing all necessary functions for protection and control of a genset. It can be used as a single unit for one genset, or it can be connected in a complete power management system with up to 32 controllers for synchronising projects, island or parallel to the mains. The power management system handles the load sharing between gensets and the load-dependent start and stop. The controller contains all necessary 3-phase measuring circuits, and all values and alarms are presented on the sun proof LCD display.
Parameter table
CM300C15N natural gas generator set | |
Genset model | CM300C15N |
Engine model | Cummin X15H-G380 |
Alternator model | Kwise |
Controller | DEIF |
Continuous output | 300kw |
Rated voltage | 400V |
Power factor | 0.8 (lagging) |
Rated frequency | 50Hz |
Rated speed | 1500rpm |
Steady state voltage regulation rate | ≤±2.5% |
Stabilization time | ≤1.5s |
Transient state voltage regulation rate | ≤ ±20% |
Fluctuation rate | ≤±0.5% |
Steady state frequency regulation rate | ≤0-5% (adjustable) |
Stabilization time | ≤5s |
Transient state frequency regulation rate | ≤±10% |
Fluctuation rate | ≤±0.5% |
Starting method | 24V DC start |
Voltage regulating method | AVR (Automatic voltage regulation) |
Speed governing method | Electronic governor |
Ignition system | Digital ignition system |
Cooling mehtod | Forced water cooling with multi-fans radiator |
Coupling method | Flexible coupling |
Reference dimension | 3800x1500x1850mm (the drawing will be presented after signing of contract) |
Reference weight | 3500kg |
Natural gas engine data | |
Model | Cummin X15H-G380 |
Engine type | Four strokes, spark plug ignited, water cooled, turbocharged and inter-cooled |
Cylinder arrangement | 6 in line |
Bore | 137mm |
Stroke | 169mm |
Displacement | 14.5L |
Rated speed | 1500rpm |
Idle speed | 850-1000rpm |
Compression ratio | 10.5:1 |
Exhaust gas temperature (after turbo) | ≤600ºC |
Exhaust gas back pressure | 10kpa |
Oil capacity | 45.4L |
Oil consumption | ≤0.4g/kwh |
Steady speed regulation | 0-5% adjustable |
Cooling method | Forced water cooling, multi-fans radiator |
Lubricating method | Pressure and splashing lubricating |
Ignition method | Spark plug ignition |
Starting method | 24V DC start |
Rotating direction | Counterclockwise (flywheel view) |
Output method | Flywheel output |
Alternator data | |
Model | Kwise |
Rated capacity | 375kva |
Rated voltage | 400V |
Rated frequency | 50Hz |
Power factor | 0.8 (lagging) |
Rated speed | 1500rpm |
Protection class | IP23 |
Insulation class | H |
Phases and connection | 3 phases and 4 wires |
Exciting method | Brushless |
Voltage regulating method | AVR automation |