- Overview
- Installation Instructions
Basic Info.
Model NO.
YDNV-300
Standard
Standard
Engine Model
Dt22
Rated Voltage
220/380V
Rated Current
540A
Speed
1500/1800rpm
Frequency
50/60Hz
Certificate
CE ISO Saso
Regulator Brand
Madas
Spark Plug Brand
Torch
Alternator
Brushless Alternator
Transport Package
for Open Type, Packing with Plywood Case; for Sile
Specification
Gas generator
Trademark
YDNPOWER
Origin
Weifang China
HS Code
8502200000
Production Capacity
500 Sets /Month
Product Description
300kw 375kva Biogas Generator Set | |||
Genset Model | YDNV-300 | ||
Rated Power (kW/kVA) | 300/375 | ||
Rated Current (A) | 540 | ||
Dimension (mm) | 3420*1700*2100 | ||
Gross Weight (kg) | 3800 | ||
Biogas Engine | Brand | VMAN | |
Model | DT22 | ||
Configuration | Four-stroke,Water-cooling,Direct Injection,12V-type | ||
Rated Power (kW/kVA) | 324/405(CH4 no less than 55%) | ||
Rated Speed (rpm) | 1500 | ||
Cylinder No. | 12.V | ||
Bore*Stroke (mm) | 128×142 | ||
Cooling Method | Water cooling | ||
Oil Consumption (g/kw.h) | 1 | ||
Gas Consumption (m3/h) | ≤180@100Load | ||
Starting method | 24V DC | ||
Gas control system | E-Throttle | BOSCH®(German Brand) | |
MIXER | IMPCO®(USA Brand) | ||
Regulator | MADAS®(Italian Brand) | ||
Spark plug | TORCH®(China Brand) | ||
Water temperature | BOSCH®(German Brand) | ||
Alternator | Brand | FARRAND | |
Model | FLD-300 | ||
Rated Power (kW/kVA) | 300/375 | ||
Material | High performance 100% copper | ||
Efficiency | 94.50% | ||
Voltage Regulation | <=±1 | ||
Voltage Regulation | Brushles, Self Excitation | ||
Insulation Class | H | ||
Control System | Brand | SMARTGEN | |
Model | HGM6110N | ||
Working Voltage | DC8.0V to DC35.0V, continuous | ||
Overall Dimensions (mm) | 197*152*47 | ||
Panel Cutout (mm) | 186*141 | ||
Working Condition | Temperature: (-25~70)ºC; Humidity: (20~90)% | ||
Weight | 0.56kg |
Requirments for Biogas
1.Methane should be at least 55%
2.The biogas temperature should be between 0-60 ºC
3. No inpurity should be in the gas. Water in the gas should be less than 20g/Nm3.
4. Heat value should be at least 5500kcal/m3, if less than this value, the power of the engine will be declined.
5. Gas pressure should be 8-14KPa, if the pressure is less than 3KPa, booster fan is necessary.
6.The gas should be dehydrated and desulfurated. Make sure that there is no liquid in the gas. H2S<200mg/Nm3
2.The biogas temperature should be between 0-60 ºC
3. No inpurity should be in the gas. Water in the gas should be less than 20g/Nm3.
4. Heat value should be at least 5500kcal/m3, if less than this value, the power of the engine will be declined.
5. Gas pressure should be 8-14KPa, if the pressure is less than 3KPa, booster fan is necessary.
6.The gas should be dehydrated and desulfurated. Make sure that there is no liquid in the gas. H2S<200mg/Nm3