Diesel generator set
1.Engine brand : Power HF Ricardo, UK brand. Volvo, MTU,Deutz , Doosan, Yanmar, Weichai etc.
2. Alternator - Optional Stamford, Leroy Somer, Marathon, JET, Mecc alte.
3.System: control system, ATS system, remote control system, parallel operation system
4.Control panel : Smartgen , Deepsea, ComAp. including digital LED genset control model: HGM6120U, DSE7320, DSE6020, AMF25.
5.Radiator :Equipped with 50°C radiator with fan, enough engine cooling system guarantee long time working
6.Canopy :Generator diesel High-quality steel are thickness canopy -- 2MM to 6MM
7.Material: high density sound-absorbing material -- sound insulation, fireproofing
8.Battery:Generator diesel 12V/ 24V DC battery with charger, battery connects wire
9.Fuel tank:Generator diesel 10-12 hours fuel tank with fuel indicator, long time for working.
10.Protection :Genset High protect class control box and power output box. IP55, Waterproof, Electric leakage protect, Breaker
11.New design of turn-back type for air inflow & air outlet which can reduce the noise and improve engine efficiency.
12.Design:Generator diesel Beautiful & practicably design, Bottom hole for forklift, water outlet & oil outlet for easy maintenance
13.Door : Double open door on both sides of the Gensets.Spacious doors can check for every part of the engine and alternator.
Diesel Generator Sets Data Sheet | ||||||||||
S/N | Ph | Power | Engine | Alternator | Genset Dimension & Weight | |||||
KVA | KW | Model | power | Model | L | W | H | KG | ||
(Kw) | (mm) | (mm) | (mm) | |||||||
HFJA-16RX | 3 | 22 | 17.6 | R3105D | 22 | PHF184FS | 2000 | 1050 | 1300 | 860 |
HFJA-24RX | 3 | 33 | 26.4 | R3105ZD | 32 | PHF184G | 2000 | 1050 | 1300 | 900 |
HFJA-30KX | 3 | 37.5 | 30 | K4102D1 | 33 | PHF184H | 2100 | 1050 | 1200 | 900 |
HFJA-32KX | 3 | 44 | 35 | K4100D-1 | 41 | PHF184J | 2100 | 1050 | 1200 | 950 |
HFJA-40RX | 3 | 55 | 44 | R4110D40-1 | 49 | PHF224D | 2300 | 1050 | 1200 | 1100 |
HFJA-50RX | 3 | 68.75 | 55 | R4105ZD1-1 | 56 | PHF224E | 2300 | 1050 | 1500 | 1200 |
HFJA-64RX | 3 | 88 | 70 | R4105IZLD-1 | 75 | PHF224G | 2500 | 1050 | 1300 | 1270 |
HFJA-75RX | 3 | 103.2 | 82.5 | R6105ZD1-1 | 84 | PHF274CS | 2800 | 1050 | 1500 | 1400 |
HFJA-80RX | 3 | 110 | 88 | R610571D-1 | 100 | PHF274C | 2800 | 1050 | 1500 | 1500 |
HFJA-90RX | 3 | 123.8 | 99 | R6105ZLD-1 | 100 | PHF274D | 2800 | 1050 | 1500 | 1600 |
HFJA-100RX | 3 | 137.5 | 110 | R6105AZLD-1 | 110 | PHF274DS | 2900 | 1050 | 1600 | 1500 |
HFJA-120RX | 3 | 165 | 144 | R6105IZLD7 | 132 | PHF274FS | 2900 | 1050 | 1600 | 1600 |
HF-160WX | 3 | 220 | 176 | WP10D200E200 | 182 | PHFD274H | 2668 | 1165 | 1507 | 1891 |
HF-180WX | 3 | 247.5 | 198 | WP10D238E200 | 216 | PHFD274J | 2668 | 1165 | 1507 | 2061 |
HF-220WX | 3 | 302.5 | 242 | WP13D320E200 | 291 | PHFD274D | 2980 | 1170 | 1780 | 2350 |
HF-500WX | 3 | 687.5 | 550 | 6M33D633E200 | 575 | PHFD5FS | 3850 | 1680 | 2100 | 5200 |
HF-800WX | 3 | 1100 | 880 | 12M26D968E200 | 880 | PHFD6F | 4800 | 2200 | 2450 | 8400 |
HF-1000WX | 3 | 1375 | 1100 | 12M33D1210E200 | 1100 | PHFD7E | 4800 | 2200 | 2450 | 8500 |
HF-1200WX | 3 | 1650 | 1320 | 12M33D1450E310 | 1350 | PHFD7F | 4800 | 2200 | 2450 | 8600 |
HF-1600WX | 3 | 2200 | 1760 | 16M33D1980E310 | 1800 | PHFD7H | 6500 | 2750 | 3058 | 16000 |
HF-2000WX | 3 | 2750 | 2200 | 12M55D2450E310 | 2200 | PHFD7K | 6600 | 2680 | 2980 | 22000 |
ITEM | PRIME | STANDBY |
Power | 30 kVA | 33 kVA |
Power | 24 kW | 26.4 kW |
Power factor | 0.8(Lagging) | |
Voltage | 400/230 V |
Prime Power - ISO 8528: Applicable for supplying power to varying electrical load for unlimited hours. Prime Power (PRP) is in accordance with ISO 8528. Ten percent overload capability is available in accordance with ISO 3046.
Standby power -ISO3046: Applicable for supplying power to varying electrical load for the duration of power interruption of a reliable utility source. Emergency Standby Power (ESP) is in accordance with ISO 8528. Fuel Stop power in accordance with ISO 3046.
Type | Soundproof |
Engine | Perkins / 1103A-33G |
Alternator | Leroy Somer / TAL-A42-C |
Controller | Comap AMF25 |
Fuel tank | 8hrs |
Noise level | 75dB@1m |
- ISO 9001 : 2015
- ISO 14001: 2015
- ISO 45001: 2018
All design for Open, Silent, Supper silent, Soundproof, Trailer, Hybrid amd container type
Q1.Are you a factory or trading company?
We are a factory. We have 500 factory workers . Welcome to visit our factory.
Q2. Is Your products the lowest price?
We take the quality into consideration prior. The price is based on the quality level and the order quantity. We have different quality level products for buyers option and discount is available from us when the order is big.
Q3.What's your warranty?
Re: All our products we offer one year warranty or 1200 hours which comes first.
Q4. If the goods in transit damage, how to do?
First of all, we will use stable packing, the possibility of the goods damaged during the shipping is low. If the goods is damaged during shipping and we covered the insurance, we will claim the insurance company and let them cover the loss. If there is no insurance cover, we will claim the shipping company and some times, we cover the loss of the goods for client.
Q5. Can we add our logo on products?
Yes, there are several ways to do this. We can put the label of your logo on the products or make the silk print of your logo on the products. It is free.
Q6. can we customize product?
OEM and ODM are welcomed from GT. We have rich experiences in this area.
Q7. What's your delivery time?
Re: 7-20 work days after we get the down payment, if your order is some special engine and alternator, then the delivery time is longer.
Q8. What's your payment?
Re: We accept T/T, L/C.